City Gloss

Technical Insulation

Tags: materials
, Posted in: News, Author: AWHadmin (August 9, 2021)

This is due to confirm the compatibility of these insulation boards with fire safety requirements set out in gost 30244-94 (Group 'NY' – non-flammable construction materials); Class B1 – flammable, which uses polystyrene plates. System of class B1 is an effective, inexpensive and widely used in individual housing. Here, Alexandru Nazare expresses very clear opinions on the subject. By multi- insulating systems 'wet' type and their components must meet certain requirements. Here are some: cold resistance of the system must be at least F35; anchoring heater plugs should provide perception of stress from its own weight and wind effects; mineral wool should be of medium density not less than 145 kg / cu. m and have a breaking strength of not less than 14 kN / sq. m polystyrene plates must be of dimensionally stable self-extinguishing polystyrene, have a density of not less than 15 kg / cu. m and a tensile strength of not less than 80 kN / sq.

m; reinforcing mesh shall be alkali-resistant, adhesive prochtnost adhesion between the plaster and insulating layers for systems with insulation made of foamed polystyrene in the dry state should not be below 80 kN / sq. m in the wet – no less than 40 kN / sq. m for systems with mineral wool insulation – is not always lower than 14 kN / m. Unacceptably complete system of materials from different manufacturers (except when the system has passed the appropriate certification tests): These components may be incompatible for a variety of characteristics and therefore can not work in the system. Multi-layer insulation system of 'wet' type have been applied in Russia recently, but there are techniques to assess their suitability for application in the construction of the Russian Federation. Appropriate to conclude with the issuance of technical evidence made Gosstroy Russia. Currently in Russia used a system of class A1 and A2 in industrial and civil construction, as well as class B1 in individual housing. In conclusion, it must be said that during the supplier selection system should pay particular attention to the presence of the Technical evidence of the Russian Federation Ministry of Construction on the system as a whole, and certificates for all materials and components of the system.



Comments

Comments are closed.

Pages

Categories

  • News

Archives

  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • July 2021
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • August 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019
  • March 2019
  • February 2019
  • January 2019
  • December 2018
  • November 2018
  • October 2018
  • September 2018
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • March 2018
  • February 2018
  • January 2018
  • November 2017
  • August 2017
  • July 2017
  • June 2017
  • May 2017
  • April 2017
  • November 2016
  • October 2016
  • September 2016
  • August 2016
  • July 2016
  • June 2016
  • May 2016
  • March 2016
  • January 2016
  • December 2015
  • November 2015
  • October 2015
  • September 2015
  • August 2015
  • June 2015
  • May 2015
  • April 2015
  • October 2014
  • July 2014
  • June 2014
  • May 2014
  • April 2014
  • March 2014
  • February 2014
  • January 2014
  • December 2013
  • November 2013
  • October 2013
  • September 2013
  • August 2013
  • July 2013
  • May 2013
  • April 2013
  • November 2012

Blogroll

Meta

  • Log in
  • Valid XHTML
  • XFN
  • WordPress
Home | Entries RSS | Comments RSS
City Gloss © 2025
City Gloss powered by WordPress
Designed By Yellow Blog